Do-160e qualifications – Rosen Aviation 0604 Series : Rosenview VX User Manual

Page 20

Advertising
background image

Rosen Aviation

RosenView VX Technical Manual

Document Number: 100640

Revision: G
Date: 9/19/12

Template: 4.4.1.6FM1; Revision A; 31 May, 2012

Page 20 of 23

5.2. DO-160E Qualifications

Table 11 DO 160E test criteria to which we test the RosenView VX

Description

DO-160E Section

DO-160E Category

Temperature and Altitude

4.0

A1

Temperature Variation

5.0

C

Humidity

6.0

A

Operational Shocks & Crash Safety

7.0

B

Vibration

8.0

S, Curve B

Explosive Atmosphere

9.0

N/A

Waterproofness

10.0

N/A

Fluids Susceptibility

11.0

N/A

Sand and Dust

12.0

N/A

Fungus Resistance

13.0

N/A

Salt Fog

14.0

N/A

Magnetic Effect

15.0

A

Power Input

16.0

Z,B

Voltage Spike

17.0

B

Audio Frequency Conducted
Susceptibility

– Power Inputs

18.0

Z

Induced Signal Susceptibility

19.0

AC

Radio Frequency Susceptibility (Radiated
and Conducted)

20.0

TT

Emission of Radio Frequency Energy

21.0

B

Lightning-induced Transient Susceptibility

22.0

N/A

Lightning Direct Effects

23.0

N/A

Icing

24.0

N/A

Electrostatic Discharge (ESD)

25.0

A

Fire, Flammability

26.0

C

Advertising