Thermo Pride Premiere XT 16 SEER User Manual

Page 11

Advertising
background image

11

FIGURE 12: Thermostat Chart - Two Stage AC – Two Stage Variable Speed Furnaces

24VAC Humidifier

(Optional)

External Humidistat

(Optional)

Open on Humidity Rise

2

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*PP32U70124

THERMOSTAT

AUX

Auxiliary Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22U00124

THERMOSTAT

W2

Second Stage Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

E/W1

Emergency Heat

E/W1

First Stage Heat

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

External Humidistat

(Optional)

Open on Humidity Rise

2

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

Thermostat Installer Setup

0170-System Type-must

be set to 8-2 Heat/2 Cool

Multistage Conventional

Connection of the “C”

terminal, 24-volt common

is optional when used with

batteries

Thermostat Installer Setup

1-System Type-must

be set to 6-2 Heat/2 Cool

Multistage Conventional

Thermostat Installer Setup
15-Compressor Protection

-must be set to 5

Part Number:

S1-2HU16700124

2

Part Numbers:

SAP = Legacy

265904 = 031-09169

1

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

TWO STAGE

VARIABLE SPEED

FURNACE CONTROL

G

Fan

TWO STAGE

VARIABLE SPEED

FURNACE

W/W1

First Stage Heat

Y/Y2

Second or Full

Stage Compressor

W2

Second Stage Heat

O

Reversing Valve

X/L

Malfunction Light

DHUM

Dehumidification

1

Move DHUM

jumper to “YES”

if humidistat is to be used.

(G/L)*(8/9)V

(F/L)*(8/9)V

PV(8/9)

ID MODELS

AC 24A

Two Stage Air Conditioner – Two Stage Variable Speed Furnace

Advertising