FIGURE 13: Thermostat Chart - Two Stage AC – Two Stage Variable Speed Furnaces

AC 24B

Two Stage Air Conditioner – Two Stage Variable Speed Furnace

Connection of the “C”

Terminal, 24-Volt Common,

is optional when used with

batteries

Part Numbers:

SAP = Legacy

265904 = 031-09169

1

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

TWO STAGE

VARIABLE SPEED

FURNACE CONTROL

G

Fan

TWO STAGE

VARIABLE SPEED

FURNACE

W/W1

First Stage Heat

Y/Y2

Second or Full

Stage Compressor

W2

Second Stage Heat

O

Reversing Valve

X/L

Malfunction Light

DHUM

Dehumidification

1

Move DHUM

jumper to “YES”

if humidistat is to be used.

(G/L)*(8/9)V

(F/L)*(8/9)V

PV(8/9)

ID MODELS

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

External Humidistat

(Optional)

Open on Humidity Rise

24VAC Humidifier

(Optional)

External Humidistat

(Optional)

Open on Humidity Rise

2

2

Part Number:

S1-2HU16700124

2

C

24 – Volt Common

R

24 – Volt Hot

Y

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22C00124

THERMOSTAT

W2

Second Stage Heat

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DP22U70124

THERMOSTAT

W2

Second Stage Heat

Step 1 of Thermostat User

Configuration Menu must

be set to MS 2

W

First Stage Heat

E/W1

First Stage Heat

Connection of the “C”

Terminal, 24-Volt Common,

is optional when used with

batteries

Advertising