Thermo Pride Premiere XT 16 SEER User Manual

Page 7

Advertising
background image

7

DEHUMIDIFICATION CONTROL

A dehumidification control accessory 2HU06700124 may be used with

variable speed air handlers or furnaces in high humidity areas. This

control works with the variable speed indoor unit to provide cooling at a

reduced air flow, lowering evaporator temperature and increasing latent

capacity. The humidistat in this control opens the humidistat contacts on

humidity rise. To install, refer to instructions packaged with the acces-

sory and Figures 7-8. Prior to the installation of the dehumidification

control, the jumper across the HUMIDISTAT terminals on the indoor

variable speed air handler or furnace CFM selection board must be

removed.
During cooling, if the relative humidity in the space is higher than the

desired set point of the dehumidification control, the variable speed

blower motor will operate at lower speed until the dehumidification con-

trol is satisfied. A 40-60% relative humidity level is recommended to

achieve optimum comfort.
If a dehumidification control is installed, it is recommended that a mini-

mum air flow of 325 cfm/ton be supplied at all times.

INDOOR CFM CONFIGURATION

For proper system operation the indoor CFM must be set properly.
Refer to the Technical Guide for the outdoor unit for the recommended

air flow settings for each size condensing unit and matching indoor unit.
Set the cooling speed per the instructions for the air handler or furnace.

Verify the airflow.
If installed as a communicating system (outdoor, indoor, and thermo-

stat), the system will automatically adjust to the optimal airflow settings.

These parameters can also be modified using the Touch Screen Com-

municating Control. Refer to the Touch Screen Communicating Control

owner’s manual for this procedure. Manual setting of the airflow on the

ID equipment is not necessary with the Touch Screen Communicating

Control.

FIGURE 7: Communicating AC with Communicating Air Handler or

Furnace

R

C

Y1

Y2

Touch Screen

Communicating

Control

Air Handler/Furnace

Communicating

Control

Air Conditioner

Communicating

Control

GND
or C

GND
or C

B-

R

A+

GND
or C

GND
or C

B-

R

A+

GND
or C

GND
or C

B-

R

A+

FIGURE 8: Communicating AC with Non-Communicating Air Handler

or Furnace using Communicating Interface Control

R

C

Y1

Y2

HUM

W2

DHUM

W

G

C

R

O

Y

Y2

HUM

W2

DHUM

W

G

C

R

O

Y

Y2

Touch Screen

Communicating

Control

Communicating

Indoor

Interface Control

Non-Communicating

Indoor Unit

Air Conditioner

Communicating

Control

Wire per

non-comm.

installation

manual

Assume that

connections

are from

thermostat

GND
or C

GND
or C

B-

R

A+

GND
or C

GND
or C

B-

R

A+

GND
or C

GND
or C

B-

R

A+