3. If the coil needs to be cleaned, use clean water to wash dust, dirt,

and debris from outdoor condensing coil.

4. Refer to the furnace or air handler instructions for filter and blower

motor maintenance.

5. The indoor coil and drain pan should be inspected and cleaned reg-

ularly to prevent odors and assure proper drainage.

SECTION VIII: AC CONTROL BOARD

FUNCTIONALITY

ANIT-SHORT CYCLE DELAY

The control includes a five-minute anti-short cycle delay (ASCD) timer

to prevent the compressor from short cycling after a power interruption

or thermostat signal interruption. The ASCD timer is applied when the

control is first powered from the indoor unit thermostat and immediately

following the completion of a compressor run cycle. The compressor

and the outdoor fan will not operate during the five minutes that the

timer is active.
The ASCD timer can be bypassed by connecting the TEST terminals

for three seconds while the thermostat is calling for compressor opera-

tion (Y1 input signal energized).

LOW VOLTAGE DETECTION

The control monitors the transformer secondary (24 VAC) voltage and

provides low voltage protection for the AC unit and its components. In

particular, the control prevents contactor chatter during low voltage con-

ditions. If the voltage drops below approximately 19 VAC, the control

will continue to energize any relays that are already energized but will

not energize any additional relays until the voltage level increases. If

the voltage drops below approximately 16 VAC, the control will immedi-

ately de-energize the relay outputs and will not energize any relays until

the voltage level increases. The control will store and display the appro-

priate fault codes when low voltage conditions occur.

TEST INPUT

The control includes a TEST input connector that can be used for vari-

ous testing functions during installation and service. Table 2 summa-

rizes the behavior of the control when the two TEST pins are

connected.

On 5 Ton unit the outdoor fan motor is a permanent magnet DC
brushless type. The motor requires a separate Electronic Control to
operate. Do not attempt to replace this motor with a typical PSC
type. Damage to Electronic Control may result.

DO NOT use coil cleaners to clean outdoor condensing coil. clean-
ers containing HF-, hydroxides, chlorides, and sulfates can greatly
reduce the lifetime of the aluminum condensing coil.

NOTICE

NOTICE

Do not connect manifold gauges unless trouble is suspected.
Approximately 3/4 ounce of refrigerant will be lost each time a stan-
dard manifold gauge is connected.

IT IS UNLAWFUL TO KNOWINGLY VENT, RELEASE OR DIS-
CHARGE REFRIGERANT INTO THE OPEN AIR DURING
REPAIR, SERVICE, MAINTENANCE OR THE FINAL DISPOSAL
OF THIS UNIT.
WHEN THE SYSTEM IS FUNCTIONING PROPERLY AND THE
OWNER HAS BEEN FULLY INSTRUCTED, SECURE THE
OWNER’S APPROVAL.

TABLE 1: R-410A Saturation Properties

TEMP. °F

PRESSURE

PSIG

TEMP. °F

PRESSURE

PSIG

TEMP. °F

PRESSURE

PSIG

TEMP. °F

PRESSURE

PSIG

TEMP. °F

PRESSURE

PSIG

45

129.70

60

169.60

75

217.40

90

274.10

105

340.50

46

132.20

61

172.60

76

220.90

91

278.20

106

345.30

47

134.60

62

175.50

77

224.40

92

282.30

107

350.10

48

137.10

63

178.50

78

228.00

93

286.50

108

355.00

49

139.60

64

181.60

79

231.60

94

290.80

109

360.00

50

142.20

65

184.60

80

235.30

95

295.10

110

365.00

51

144.80

66

187.70

81

239.00

96

299.40

111

370.00

52

147.40

67

190.90

82

242.70

97

303.80

112

375.10

53

150.10

68

194.10

83

246.50

98

308.20

113

380.20

54

152.80

69

197.30

84

250.30

99

312.70

114

385.40

55

155.50

70

200.60

85

254.10

100

317.20

115

390.70

56

158.20

71

203.90

86

258.00

101

321.80

116

396.00

57

161.00

72

207.20

87

262.00

102

326.40

117

401.30

58

163.90

73

210.60

88

266.00

103

331.00

118

406.70

59

166.70

74

214.00

89

270.00

104

335.70

119

412.20