Thermo Pride Spirit Gas TG8S Single Stage PSC 80% User Manual

Page 28

Advertising
background image

998491-UIM-B-1013

28

Johnson Controls Unitary Products

DIAGNOSTIC FAULT CODE STORAGE AND

RETRIEVAL

The control in this furnace is equipped with memory that will store up to
five error codes to allow a service technician to diagnose problems
more easily. This memory will be retained even if power to the furnace
is lost. This feature should only be used by a qualified service tech-
nician.

If more than five error codes have occurred since the last reset, only the
five most recent will be retained. The furnace control board has a but-
ton, labeled "LAST ERROR" that is used to retrieve error codes. This
function will only work if there are no active thermostat signals. So any
call for heating, cooling or continuous fan must be terminated before
attempting to retrieve error codes.

To retrieve the error codes, push the LAST ERROR button. The LED on
the control will then flash the error codes that are in memory, starting
with the most recent. There will be a two-second pause between each
flash code. After the error codes have all been displayed, the LED will
resume the normal slow green flash after a five second pause. To
repeat the series of error codes, push the button again.

If there are no error codes in memory, the LED will flash two green
flashes. To clear the memory, push the LAST ERROR button and hold it
for more than five seconds. The LED will flash three green flashes when
the memory has been cleared, then will resume the normal slow green
flash after a five-second pause.

SECTION X: REPLACEMENT PARTS LIST

DESCRIPTION

MOTOR

MOTOR, DIRECT DRIVE BLOWER

BLOWER, COMBUSTION

ELECTRICAL

CAPACITOR, RUN

SWITCH, LIMIT

CONTROL, FURNACE

IGNITER

SENSOR, FLAME

SWITCH, PRESSURE

SWITCH, DOOR

TRANSFORMER

VALVE, GAS

CONTROL, TEMPERATURE

AIR MOVING

HOUSING, BLOWER

HOUSING, BLOWER w/WHEEL

WHEEL, BLOWER

FABRICATED PARTS

BAFFLE, FLUE

BURNER, MAIN GAS

BRACKET, IGNITER

SHELF, BLOWER

RAIL, BLOWER (2 Req’d)

FABRICATED PARTS

BRACKET, BLOWER TRACK (2 Req’d)

HEAT EXCHANGER ASS’Y

MANIFOLD, GAS

PAN, BOTTOM

PANEL, TOP

PANEL, DOOR (2 Req’d)

VENT PAN, COMBUSTION (w/Gasket)

PANEL, BLOCKOFF

LO-NOX SCREEN (L-Models Only)

MISCELLANEOUS

ORIFICE, BURNER (Natural #45)

SIGHT GLASS, OVAL (2 Req’d)

GASKET, FOAM (Door) (1.5 ft req’d)

GASKET, INTAKE PAN

PLUG, VENT HOLE

BRACKET, DOOR

WIRING HARNESS

FERRULE (3 Req’d)

GROMMET (3 Req’d)

MOTOR MOUNT

TUBING, SILICON

DIAGRAM, WIRING

KNOB, QUARTER TURN (4 Req’d)

DESCRIPTION (Continued)

REPLACEMENT PART CONTACT INFORMATION

This is a generic parts list. To request a complete parts list, refer to the contact information below:

• Visit our website at www.source1parts.com for the following information:

1. Search for a part or browse the catalog.

2. Find a dealer or distributor.

3. Customer Service contact information.

a. Click on the “Brand Links” button

b. Click on the “Customer Service” button

• You can contact us by mail. Just send a written request to:

Johnson Controls Unitary Products

Consumer Relations

5005 York Drive

Norman, OK 73069

Advertising