SECTION III: FILTERS

FILTER INSTALLATION

All applications require the use of a field installed filter. All filters and
mounting provision must be field supplied.

Filters must be installed external to the furnace cabinet. DO NOT
attempt to install filters inside the furnace.

1. Air velocity through throwaway type filters may not exceed 300 feet per min-

ute (91.4 m/min). All velocities over this require the use of high velocity fil-
ters.

2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For

CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.

FIGURE 12: Dimensions

LEFT SIDE

RIGHT SIDE

.5”

.5”

RETURN END

B

24.25”

29.5”

28.5”

Electrical
Entry

Gas Pipe
Entry

Thermostat
Wiring

FRONT

14”

1”

1.5”

23”

SUPPLY END

C

24.38”

20”

.5”

B

Gas Pipe
Entry

Thermostat
Wiring

33”

A

.5”

Electrical
Entry

Vent Connection
Outlet

Vent
Connection
Outlet

4” Diameter

Outlet

Vent Connection

Table 3: Cabinet and Duct Dimensions

BTUH (kW)

Input

Nominal

CFM (m

3

/min)

Cabinet

Size

Cabinet Dimensions (Inches)

Approximate

Operating Weights

A

A (cm)

B

B (cm)

C

C (cm)

Lbs

40 (11.7)

800 (22.7)

A

14 1/2

36.8

13 3/8

34.0

10.3

26.2

89

60 (17.6)

1000 (28.3)

A

14 1/2

36.8

13 3/8

34.0

10.3

26.2

91

60 (17.6)

1200 (34.0)

A

14 1/2

36.8

13 3/8

34.0

10.3

26.2

94

80 (23.4)

1200 (34.0)

B

17 1/2

44.4

16 3/8

41.6

11.8

29.9

103

80 (23.4)

1600 (45.3)

C

21

53.3

19 7/8

50.5

13.6

34.5

114

80 (23.4)

2200 (62.3)

C

21

53.3

19 7/8

50.5

13.6

34.5

119

100 (29.3)

1200 (34.0)

B

17 1/2

44.4

16 3/8

41.6

11.8

29.9

108

100 (29.3)

1600 (45.3)

C

21

53.3

19 7/8

50.5

13.6

34.5

118

100 (29.3)

2000 (56.6)

C

21

53.3

19 7/8

50.5

13.6

34.5

122

120 (35.1)

1600 (45.3)

C

21

53.3

19 7/8

50.5

15.8

40.1

123

120 (35.1)

2000 (56.6)

C

21

53.3

19 7/8

50.5

15.8

40.1

129

130 (38.1)

2000 (56.6)

D

24 1/2

62.2

23 3/8

59.4

17.5

44.4

135

Single side return above 1800 CFM is approved as long as the filter
velocity does not exceed filter manufacturer’s recommendation.

NOTICE

Table 4: Recommended Filter Sizes (High Velocity 600 FPM)

CFM

(m³/min)

Cabinet

Size

Side

(in)

Bottom

(in)

800 (22.7)

A

16 x 25

14 x 25

1000 (28.3)

A

16 x 25

14 x 25

1200 (34.0)

A

16 x 25

14 x 25

1200 (34.0)

B

16 x 25

16 x 25

1600 (45.3)

B

16 x 25

16 x 25

1600 (45.3)

C

16 x 25

20 x 25

2000 (56.6)

C

(2) 16 x 25

20 x 25

2200 (62.3)

C

(2) 16 x 25

20 x 25

2000 (56.6)

D

(2) 16 x 25

22 x 25