Installation and Operation, cont’d

2-8

MTP 4T 15HD RS • Installation and Operation

2-9

Receiver considerations

N

Each transmitter in the assembly requires a separate

receiver.

N

The receivers' buffered outputs do not provide pre-

peaking control. The total recommended distance for an

entire daisy chain is the same as for a single transmitter

and receiver. The transmitter's Pre-Peak switch has the

same affect on the recommended transmission distance

for a daisy chain as for a single transmitter and receiver.

N

Up to 8 receivers can be connected in series to a

transmitter using the receivers' Buffered Output

connectors, provided that the total distance from the

transmitter’s TP output to the last receiver in the

chain does not exceed the recommended distance for the

resolution being used.

N

See the recommended transmission ranges in the table

on page 1-4. The recommendations in the table apply

equally for a single transmitter and receiver and for a

transmission daisy chain. For example, the maximum

suggested range for 1024 x 768 video is 300’ with

Pre-Peak off and 500’ with Pre-Peak on for either one

transmitter and one receiver or a transmitter and three

daisy-chained receivers.

N

For daisy-chained units, the first receiver in the chain

must be at least 100’ from the transmitter when the Pre-

Peak switch is on.

N

For daisy-chained units, any receiver in the chain closer

than 350’ may experience some form of over-peaking

when the Pre-Peak switch is on.

N

If a receiver is the last receiver in a daisy chain, its end

unit DIP switch setting needs to be changed. Refer to

the

MTP 15HD RS Series manual.

Front Panel Controls and Indicators

Figure 2-6 shows the front panel of the MTP 4T 15HD RS and its

power LED.

1

Figure 2-6 — MTP 4T transmitter front panel

a

Power LED — Indicates power is applied to the

MTP 4T 15HD RS.

Skew Delay Compensation

CAT 5/5e/6 TP cable can lead to registration errors between the

red, green, and blue video signals. Pair skew can be measured

with test equipment or identified by viewing a crosshatch test

pattern with a critical eye to determine if either the red, green,

or blue video image leads (appears to the left of) the other two

video images.

N

Unless the TP cable is changed, the skew adjustment

should only need to be made once, during installation.

SEQ receiver skew compensation

The MTP 15HD RS SEQ receiver has built-in skew compensation

capabilities. Refer to the MTP 15HD RS Series manual for details.

Non-SEQ receiver skew compensation

Try using the following methods to minimize or eliminate pair

skew:
• Switch to Extron’s Enhanced Skew-Free A/V UTP cable.
• Add a skew compensation cable equal to the length of

pair skew to the receiver’s output.

• Install an SEQ 100 15HD Skew Equalizer on the receiver’s

video output and adjust the skew for the leading video

image.