MTP 4T 15HD RS • Installation and Operation

Installation and Operation

MTP 4T 15HD RS • Installation and Operation

2-2

2-3

Setting the Transmitter Sync Jumpers

(Component Video)

By default, each transmitter in the MTP 4T 15HD RS is

configured to send bi-level (normal) sync. For HDTV/component

video applications, the transmitter can be configured to send

tri-level sync as follows:
1

.

If applicable, disconnect all power and other cables,

remove the transmitter from its installation location, and

remove any previously installed mounting brackets.

2

.

Remove the eight screws (three on each side and two on

top) from the transmitter assembly and lift the top cover

off of the transmitter (figure 2-1).

INPU

T

Tx

Rx

RS

-23

2

MO

NIT

OR

OU

TP

UT

MT

P 4

T 1

5H

D

RS

4

MT

P 4

T 1

5H

D

RS

3

MT

P 4

T 1

5H

D

RS

2

MT

P 4

T 1

5H

D

RS

1

PRE

-PE

AK

ON

OFF

INPU

T

Tx

Rx

RS

-23

2

MO

NIT

OR

OU

TP

UT

PRE

-PE

AK

ON

OFF

INPU

T

Tx

Rx

RS

-23

2

MO

NIT

OR

OU

TP

UT

PRE

-PE

AK

ON

OFF

INPU

T

Tx

Rx

RS

-23

2

MO

NIT

OR

OU

TP

UT

PRE

-PE

AK

ON

OFF

Lift Cover
Straight Up

For each
transmitter:

Remove (8)
Screws from
Top & Sides

T

N

T

N

T

N

J6

Tri-level

Sync

Normal

(Bi-level

Sync)

Figure 2-1 — Opening the transmitter assembly and
sync jumpering

N

There are four transmitter boards. Ensure that you set

the jumper on the correct board.

3

.

Locate jumper J6 on the main (bottom) board and shift the

jumper from the normal sync (N) to the tri-level sync (T)

position (figure 2-1).

4

.

Place the top cover back into place.

5

.

Reinstall the screws removed in step 2. If any mounting

brackets were removed in step 1, put them back into

position as you reinstall the screws.

6

.

If applicable, reinstall the transmitter assembly and

reconnect all cables.

Installation

C

Installation and service must be performed by

authorized personnel only.

The MTP 4T 15HD RS is 1U high and a full rack wide. It is rack

mountable, or it can be placed on a table or other furniture.

Rubber feet and rack mounting hardware are included.

Tabletop placement

For tabletop use, attach one of the self-adhesive feet to each

corner of the bottom side of the unit and place the unit in the

desired location.

Rack mounting

UL requirements

The following Underwriters Laboratories (UL) requirements

pertain to the installation of the unit into a rack.
1.

Elevated operating ambient temperature

— If the

equipment is installed in a closed or multi-unit rack

assembly, the operating ambient temperature of the

rack environment may be greater than room ambient.

Therefore, consider installing the equipment in an

environment compatible with the maximum 122° F (50° C)

ambient temperature (Tma) specified by the manufacturer.

2.

Reduced air flow

— Installation of the equipment in a rack

should be such that the amount of air flow required for

safe operation of the equipment is not compromised.

3.

Mechanical loading

— Mounting of the equipment in

the rack should be such that a hazardous condition is not

achieved due to uneven mechanical loading.

4.

Circuit overloading

— Consideration should be given to

the connection of the equipment to the supply circuit and

the effect that overloading of the circuits might have on

overcurrent protection and supply wiring. Appropriate

consideration of equipment nameplate ratings should be

used when addressing this concern.