Maintenance and modifications, cont’d – Extron electronic HSA 200SE User Manual

Page 19

Advertising
background image

HSA 200/222 Series • Maintenance and Modifications

HSA 200/222 Series • Maintenance and Modifications

Maintenance and Modifications, cont’d

3-6

4

.

Remove the four 1/16" hex head screws on the right and
left sides of the front panel (figure 3-3). Retain the screws.
Lift the panel away from the enclosure.

Figure 3-3 shows an HSA 200 model. Removing the
front panel from an HSA 222 is an identical procedure.

Lift p

a

nel o

u

t

of enclo

su

re.

Remove 2 hex he

a

d

s

crew

s

on e

a

ch

s

ide.

240 - 50/60 Hz 5A

HSA 200

AUDIO

Figure 3-3 — Removing the front panel

5

.

With a Tweeker, push down on and
gently twist on the front of each RJ-45
connector detent to disconnect the
connector from the rear of the front panel
plug-in.

6

.

Pinch the top and bottom bezel detents
together and push the bezel through the
front panel.

7

.

Snap a replacement bezel in place. If necessary, replace the
connector icon by prying the old icon off of the connector
plug-in with a Tweeker (figure 3-4) and snapping a new
icon in place.

Icon La

b

el

Figure 3-4 — Changing the connector icon

8

.

Snap the internal RJ-45 connector onto the back of the front
panel enclosure bezel plug-in.

9

.

(HSA 222 models only)

Reach your hand through the

front panel access hole and snap the lower internal RJ-45
connectors onto the back of the lower enclosure bezel
plug-ins.

10

.

Replace the front panel in the surface mount enclosure and
secure it in place with the hex head screws removed in
step 4.

11

.

(HSA 222 models only)

Replace the front access panel in

the surface mount enclosure and secure it in place with the
Philips head screws removed in step 2.

12

.

(HSA 222 models only)

Reinstall the surface mount

enclosure. See Removing and Replacing the Enclosure, steps 6
through 11.

3-7

Advertising