HSA 200/222 Series • Maintenance and Modifications

HSA 200/222 Series • Maintenance and Modifications

Maintenance and Modifications, cont’d

3-10

7.

(HSA 222 models only)

Remove the four Philips head

screws from the front access panel (figure 3-7). Retain the
screws. Lift the panel away from the enclosure.

Remove
front access
panel.

Figure 3-7 — Front access panel removal (HSA 222
models)

8

.

Remove the pivot nut from the upper pivot bolt, then
remove the bolt, releasing the upper end of the gas lift
from the top panel. Pull the gas lift from the bottom of the
enclosure.

HSA 200 models

— Reach through the front panel

opening (figure 3-8).

HSA 222 models

— Reach through the front access panel

(figure 3-9 on page 3-12).

Top Clevis

Gas Lift

Piston End

Pivot Bolt

Pivot N

u

t

Figure 3-8 — Replacing the gas lift, HSA 200 model

3-11