Maintenance and Modifications

HSA 200/222 Series • Maintenance and Modifications

HSA 200/222 Series • Maintenance and Modifications

3-2

The most probable corrective maintenance procedures for your
HSA 200 or HSA 222 are leveling the top surface and replacing
the gas lifts. Most of the maintenance procedures require
removing the surface mount enclosure from the table.

Removing and Replacing the Enclosure

The procedure for replacing the bezel in an HSA 222 only
requires removing the HSA from the table.

The procedure for replacing the gas lift requires removing
the HSA 200 or HSA 222.

The procedure for levelling the top surface may require
removing the HSA.

Remove and replace the surface mount enclosure for
maintenance as follows:

Ensure that AC power is disconnected before
servicing the HSA unit.

1

.

Disconnect:

The IEC power cord

The RJ-45 connectors from the underside of the surface
mount enclosure

(HSA 200 models only)

Any device plugged into the AC

power outlet

(HSA 200 models only)

The BNC (video) connectors

(HSA 200 models only)

The audio connector

(HSA 200CE and HSA 200SE only)

The power supply

connector

2

.

Loosen the locking
thumbscrews on the screw
clamps to unlock the clamp.

3

.

Loosen the screw clamps.

4.

Remove the screw clamps on
both sides of the enclosure.
Lift the enclosure from the table.

CAUTION

The flanged edges of the top of the surface enclosure
are bevelled to an ultra-fine thickness of less than
0.04 (4/100)” (approximately 1 mm), and are
therefore very sharp. These edges are also soft and
may be easily nicked or bent. Exercise caution
when handling and mounting the enclosure.
Mishandling may result in injury to the installer or
damage the appearance of the enclosure.

The surfaces of the HSA enclosure have screws and other
protrusions that could damage fine furniture. Do not
rest the enclosure on unprotected furniture.

5

.

Perform the desired maintenance procedure.

6

.

If the surface is not level, adjust the top surface. See
“Adjusting the Top Panel” in this chapter.

7

.

Carefully lower the HSA enclosure into the table opening.

8

.

From the underside of the table, reinstall the screw clamps
on the enclosure at a height at which the clamp will reach
the underside of the tabletop.

9

.

Snugly tighten the Philips head screws on the screw
clamps to secure the enclosure to the surface.

CAUTION

Overtightening the Philips head screws on the screw
clamps can bend the clamp’s horizontal flange.

10

.

Tighten the locking thumbscrews on the screw clamps to
lock the clamp in position.

11

.

Reconnect all of the connectors removed in step 1.

Replacing the Bezels

The HSA ships with RJ-45/RJ-11 connector bezel plug-ins in a
variety of colors and a black, blank bezel.

To change to a different color connector bezel or if a connector is
not needed, replace the connector bezel
plug-in on the front panel with a bezel of
a different color or a blank plug-in.

If no connector is desired, snap the
interior RJ-45 connector onto the rear of
the blank bezel plug-in to hold it
conveniently out of the way. Retain the
removed connector bezel plug-in for later use.

Replace a bezel as follows:

1

.

(HSA 222 models only)

Remove the surface mount

enclosure from the table. See “Removing and Replacing
the Enclosure”, steps 1 through 4.

3-3

Thumbscrew

Screw
Clamp

Advertising