Avago Technologies MegaRAID SAS 9240-4i User Manual

Page 14

Advertising
background image

LSI Corporation

- 14 -

StorCLI Reference Manual

January 2013

Chapter 4: Working with the Storage Command Line Tool

Controller Commands

cacheflushint

0 to 255, default value 4

Sets cache flush interval in seconds.

ccrate

0 to 100

Sets consistency check rate in percentage.

coercion

0

: No coercion

1

: 128 MB

2

: 1 GB

Sets drive capacity in coercion mode.

consistencycheck

See Section

4.2.3.3

,

Consistency Check

.

See Section

4.2.3.3

,

Consistency Check

.

copyback

on|off

type = smartssd|smarthdd|all

smartssd

: Copy back enabled for SSD

drives.

smarthdd

: Copy back enabled for HDD

drives.

all

: Copy back enabled for both ssd

drives and HDD drives.

Example:

storcli /cx set copyback=on
type=all

Enables/disables copy back for drive types.

directpdmapping

on|off

Enables/disables direct physical drive mapping. When
enclosures are used, this feature is disabled; otherwise it
should be enabled.

eccbucketleakrate

0 to 65535

Sets leak rate of the single-bit bucket in minutes (one
entry removed per leak-rate).

eccbucketsize

0 to 255

Sets size of ECC single-bit-error bucket (logs event
when full).

enableeghsp

on|off

Enables/disables the commissioning of otherwise
incompatible global hot spare drives as Emergency Hot
Spare (EHSP) drives.

enableesmarter

on|off

Enables/disables the commissioning of Emergency Hot
Spare (EHSP) drives for Predictive Failure (PFA) events.

enableeug

on|off

Enables/disables the commissioning of Unconfigured
Good drives as Emergency Hot Spare (EHSP) drives.

exposeencldevice

on|off

Enables/disables device drivers to expose enclosure
devices; for example, expanders, SEPs.

dimmerswitch|ds

See Section

4.8

,

Dimmer Switch

Commands

.

See Section

4.8

,

Dimmer Switch Commands

.

foreignautoimport

on|off

Imports foreign configuration automatically, at boot.

jbod

on|off

Enables/disables JBOD mode; by default, drives become
system drives.

NOTE Not supported by all controllers.

loadbalancemode

on|off

Enables/disables automatic load balancing between SAS
phys or ports in a wide port configuration.

maintainpdfailhistory

on|off

Maintains the physical drive fail history.

migraterate

0 to 100

Sets data migration rate in percentage.

patrolread|pr

See Section

4.2.3.2

,

Patrol Read

.

See Section

4.2.3.2

,

Patrol Read

.

Table 4 Properties for Show and Set Commands (Continued)

Property Name

Set Command Range

Description

Advertising