3.4.4 Connection Errors

If ControlScape FH is not able to communicate with a radio, it will open a
message box describing the problem.

To troubleshoot communication problems, follow these steps:
 Verify that you can communicate with the Master radio through an ethernet

cable connection (page 59)

 Verify that the Master radio and remote radios are powered up (page 56)
 Verify that the Remote radios are connected to antennas, (page 56) and are

correctly sited (page 57) to receive signals from the Master radio

 Verify that the computer's IP address and the IP addresses of the radios are

on the same network (page 58)

 Eliminate sources of interference (page 70).
If you are still unable to connect to a radio, contact ProSoft Technical Support
(page 99) for assistance.