Installing the chassis, Table-top installation, Rack mount installation – Enterasys Networks X-Pedition 2000 User Manual

Page 42: Table-top installation rack mount installation

Advertising
background image

Installing the Hardware

26

Enterasys Xpedition 2000 Getting Started Guide

Installing the Chassis

Enterasys recommends that only qualified personnel conduct installation of any XP chassis.

Warning

: Before performing any upgrade or installation procedures, ensure that the

XP-2000 is powered off.

This section contains procedures for the following types of installation:

Table-top installation

Rack mount installation

Table-Top Installation

You can install the XP-2000 on a tabletop.

1.

Select a table that is stable (not wobbly) and is not in an area subject to frequent foot traffic.
Remember that you will be attaching numerous cables to the XP-2000.

2.

Place the XP-2000 on the table, allowing at least 3” of space on each side for adequate air flow
to the cooling fans.

Rack Mount Installation

You can install the XP-2000 in a standard 19” equipment rack. The XP-2000 chassis contains screw
holes for front-mounting brackets.

Note:

Never attempt to rack mount the XP-2000 unaided. Ask an assistant to help you hold the
chassis.

To install the XP-2000 chassis in an equipment rack, use the following procedure. You need a
phillips-head screwdriver to perform this procedure.

Figure 9

shows an example of how to install the XP-2000 in an equipment rack. The procedure

following the figure describes how to install the XP-2000 in an equipment rack.