Setting the Operation Mode

MODE SW 6/7

This specifies the audio channels assigned to signals from the AUDIO OUT connectors.
Combinations of 6 and 7 specify the assigned channels as described below.

6

OFF

7

OFF

Channels 1 and 2 assigned

6

ON

7

OFF

Channels 3 and 4 assigned

6

OFF

7

ON

Channels 5 and 6 assigned

6

ON

7

ON

Channels 7 and 8 assigned

MODE SW 8

This specifies the enabled video source.

OFF

SDI input is enabled

ON

HDMI input is enabled

MODE SW 9

This specifies the type of 3G-SDI output coming out from the SDI OUT connector.

* The signal type of SDI IN is detected automatically.

OFF

Output with Level A mapping structure

ON

Output with Level B mapping structure

MODE SW 10

This specifies the control mode.

* This also enables/disables the AUTO OFF function (p. 13).

OFF

Mode is controlled by switches 1-9..

ON

The unit operates according to the settings in the internal memory (Set with VC-1
RCS software)

You can carry out detailed settings and save to unit’s internal memory using the
dedicated remote control software, the VC-1 RCS (p. 26).

About the Delay Dials

These set the amount of delay for video and audio. You can set the amount of delay
independently for video and audio, in a range of 0 to 9 fields (0 to 4.5 frames) for each.

* When there is input to the REF IN connector, the delay caused by the frame-synchronizer

operation is added to the amount you have set.