Summit 200-24 switch, Appendix b, Technical specifications – Extreme Networks 200 Series User Manual

Page 301

Advertising
background image

Summit 200 Series Switch Installation and User Guide

299

B

Technical Specifications

This appendix provides technical specifications for the following Summit 200 series switches:

Summit 200-24 Switch on page 299

Summit 200-48 Switch on page 302

Summit 200-24 Switch

Physical and Environmental

Dimensions

Height: 1.75 inches (4.44 cm)
Width: 17.3 inches (43.94 cm)
Depth: 8.1 inches (20.57 cm)

Weight

Weight: 5.72 lbs (2.6 kg)

Temperature and Humidity

Operating Temperature: 0° to 40° C (32° to 104° F)
Storage Temperature: –40° to 70 ° C (–40° to 158° F)
Operating Humidity: 10% to 95% relative humidity,
noncondensing
Standards: EN60068 to Extreme IEC68 schedule EN 300 019

Power

AC Line Frequency: 50 Hz to 60 Hz
Input Voltage Options: 90 VAC to 264 VAC, auto-ranging
Current Rating: 100-120/200-240 VAC 2.0/1.0 A 0.5/0.25A

Heat Dissipation, Watts/BTU

24.1 W

Temperature switch power-off

(Listed by supply type)

Digital supplies, not Rev. C1:
Not drifting: 65° to 70° C (149° to 158° F)
Drifting: 50° C (122° F)

Digital supplies, Rev. C1: 70° to 75° C (158° to 167° F)

Power-One supplies, Rev. OL and earlier: 60° to 65° C
(140° to 149° F)

Power-One supplies, Rev. OM and later: 75° C (167° F)