Schematic of straight-through and crossover cables, Used, Figure 3-7 – Enterasys Networks 2H252-25R User Manual

Page 37: Straight-through cable crossover cable

Advertising
background image

Connecting to the Network

Installation

3-11

Figure 3-7

Schematic of Straight-Through and Crossover Cables

4. Verify that a link exists by checking that the port RX LED is on (flashing amber, blinking green,

or solid green). If the RX LED is off and the TX LED is not blinking amber, perform the
following steps until it is on:

a. Verify that the device at the other end of the twisted pair segment is powered up.

b. Verify that the RJ45 connector on the twisted pair segment has the proper pinouts.

c. Check the cable for continuity.

d. Make sure that the twisted pair connection meets the db loss and cable specifications outlined

in

Section 2.3

.

e. If a link is not established, contact Enterasys Networks. Refer to

Section 1.2

for details.

5. Repeat steps 1 through 4 for each connection until all connections have been verified.

TX+

TX–

RX+

RX–

2

1

3

6

TX+

TX–

2

1

3

6

NOTE:

RX+/RX– and TX+/TX–

must share a common

color pair.

TO

SmartSwitch RJ45 Port

25041-08

RJ45 to RJ45

RX+

RX–

TX+

TX–

RX+

RX–

2

1

3

6

TO

10BASE-T or 100BASE-TX

Device Port

TX+

TX–

2

1

3

6

RJ45 to RJ45

RX+

RX–

TO

SmartSwitch RJ45 Port

Straight-Through Cable

Crossover Cable

TO

10BASE-T or 100BASE-TX

Device Port

Advertising