Enterasys Networks 2H252-25R User Manual

Page 43

Advertising
background image

Using LANVIEW

Troubleshooting

4-5

TX
(Transmit)

Off

Port enabled, and no
activity.

Should flash green every
two seconds indicating
BPDUs being sent if STA is
enabled and there is a valid
link.

1. Ensure that the STA is enabled

and that there is a valid link.

2. Contact Enterasys Networks for

assistance.

Green

Flashing. Indicates activity.
Rate indicates data rate.

None.

Amber

Blinking. Port in standby.

Port may be disabled due to
Spanning Tree.

1. Ensure that the port is not

disabled.

2. Contact Enterasys Networks for

assistance.

Red

Flashing. Indicates collision
rate.

None, unless there is a large
amount of activity. In this case,
check for network configuration
problems or a defective device.

Solid. Diagnostic failure.

Contact Enterasys Networks for
assistance.

The following port DPX and SPD LED indications are only valid when the LED MODE switch
is in the DPX-SPD position.

FDX

(Full
Duplex
Status)

Amber

Port is operating in standard
mode (10 Mbps or
100 Mbps).

None.

Green

Port is operating in full
duplex mode (20 Mbps or
200 Mbps).

None.

SPD (Speed
Status)

Amber

There is a link and the port
is operating at 10 Mbps.

None.

Green

There is a link and the port
is operating at 100 Mbps.

None.

Table 4-1

LANVIEW LEDs (Continued)

LED

Color

State

Recommended Action

Advertising