Initial installation – Enviro DV42DX User Manual

Page 14

Advertising
background image

Initial Installation

QUALIFIED INSTALLERS ONLY

i

ntRoDuction

:

This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement,

hearths, facings, mantels, and venting terminations will be covered, as well as the gas and electric

systems. There are several installation safety guidelines that must be adhered to. Please carefully read

the safety precautions at the front of this manual.

P

Lacement

:

The location for the fireplace can be along a wall, raised or at floor level, or in a corner. There are specific

framing measurements for each situation. The basic opening should have the dimensions shown below

in Figure 15.

Warning: Clearances must be sufficient

to allow access for maintenance and

service.
The fireplace must have a strong and

level surface to be placed on. The surface

should be made of wood or a non-

combustible material, not carpet.
The 19½ inches (494 mm) dimension

takes into account the 1 inch (25 mm)

standoff on the back of the firebox. The

framing boards may touch the standoffs,

but no insulating material can be

placed between the frame and the

standoffs.
The gas line,

3

/

8

” NPT, should be brought

to the right side of the fireplace. If this

set up is inconvenient, the electrical wire

and the gas line configuration can be

reversed.
The location should be chosen so the

fireplace will be at least 36 inches (914

mm) from drapes, doors and other

combustibles. The fireplace opening

should also be at least 5 inches (127

mm) from the nearest perpendicular wall

(sidewall to the edge of the opening).

19

1

/

2

"

(49

4m

m)

42"

(10

67m

m)

41

1

/

4

"

(1046mm)

Gas Line

Electrical Line

Figure 15. Dimensions for Framing the Firebox.

14