Initial installation – Enviro DV42DX User Manual

Page 19

Advertising
background image

Flue Pipe Adaptor

Wall Framing

Wall Thimble

Fire Stop

Exhaust 4" Flex Pipe

Combusion Air 6 5/8" Flex Pipe

Wire Spacers

Horizontal Vent Termination

19

INSTALLATION INSTRUCTIONS:
1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet

the clearances noted in the venting section, and any or all local code requirements.

Wire

spacers

Figure 25: Wire Spacers.

2. Set the appliance in the desired location. Determine if any wall studs,

electrical wiring, or plumbing pipes are in the way of the venting system as

it passes through the exterior wall. The fireplace location should be adjusted

if obstructions are found in the wall.

3. Project a line from the center point of the flue outlet upward and outward to

the desired flue outlet location on the exterior wall. Using this center point,

Initial Installation

QUALIFIED INSTALLERS ONLY

Figure 26: Wire Spacer in Place.

scribe a 10” (25.4 cm) hole or square on the

wall. Cut the hole from the interior through

the exterior wall surfaces.

4. Frame the hole as shown in Figure 29.
5. Trim the wall thimble to match the wall

thickness as necessary. Install the wall

thimble and secure it to the inner wall

frame using four (4) 1½” wood screws. If

a wall is greater than 8” (203mm) in depth,

the clearance above the flex must be 4⅜”

(111mm)

Figure 27: Installation of Fireplace Horizontal Vent Kit.

6. Apply a bead of Mill-Pac Black

sealant to the new Ø4” (10 cm) by

5” (12.5 cm) provided flue collar

adaptor. Press the flue collar into

the flue outlet of the fireplace so

that the Mill-Pac seals the flue

collar to the flue outlet.

7. Stretch both the Ø4” (10 cm) flex

vent and the Ø6⅝” (16.25 cm) flex

intake liner to the length needed

to ensure the flex can be easily

connected to the vent terminal.

8. Slide the Ø6⅝” (16.25 cm) flex

intake liner over the flex vent.

Install four (4) wire spacers

around the flex pipe. Ensure the

wire spacers are positioned at

either end of the pipes, and at

each end of any elbows in the

liners (refer to Figure 25 and 26).

Advertising