Maintenance And Service

b) Insert a

5

/

32

” or 4 mm Allen wrench into the

hexagonal key-way of the screw (see Figure 10),

rotate it counter-clockwise until it is free and

extract it.

c) Check that the screw is clean and if necessary

remove dirt.

d) Flip the screw (refer to Figure 11).
e) Using the Allen wrench as shown in Figure 10,

rotate the screw clockwise until a torque of 9 inch

lbs. WARNING! Do not over tighten the screw.

It is recommended that you grip the wrench by

the short side.

f) Verify that if the conversion is from NG to LPG,

the screw must be re-assembled with the red o-

ring visible (refer to Figure 12). If the conversion

is from LPG to NG, the red o-ring of the screw

must be not visible.

Figure 11: Flip valve

screw.

g) Re-attach the black protection

cap that was removed in step a

(Figure 9).

8. Reinstall the burner, brick panels,

log set, embers, and glass door.

Also refer to S

ECONDARY

I

NSTALLATION

- I

NSTALLING

L

OG

S

ET

AND

E

MBERS

. When

re-installing the burner, ensure that

the pilot hood in in line with the

Figure 12: O-ring on valve screw.

small hole at the edge of front and rear burner. On some units you will need to pay special attention

when installing the burner that the venturi adjustment rod is properly installed into the venturi

adjustment piece welded to the burner venturi tube

9. Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the

unit.

10. Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap

and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by

using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN

TESTING FOR LEAKS.

11. Reconnect the electrical power to the unit.
12. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and

operation and proper flame appearance. Also refer to S

ECONDARY

I

NSTALLATION

- L

OG

S

ET

AND

E

MBERS

I

NSTALLATION

for a flame appearance picture.

13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the

unit has been converted to a different fuel type.

Figure 10: Removing valve

screw.

7. Convert the SIT gas valve:

a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 9.