Initial Installation

QUALIFIED INSTALLERS ONLY

Figure 21: Assembly of Venting Kit.

Wall framing

Horizontal wall

termination

Wall thimble

fire stop

Inside finished collar

Decorative

brass rings

Exhaust 4"

flex pipe

Combustion air

6

5

/

8

" outer pipe

Flue pipe adaptor

11. Stretch the liner out. Attach the flexible liner to the vent termination cap by placing a small bead of

high temperature silicone on the vent termination and slide the flex liner onto the vent terminal and

secure with three (3) sheet metal screws evenly spaced.

12. Dress the flex liner through the wall thimble and attach the vent terminal to the outside of the house

using four (4) wood screws provided. The use of non-hardening mastic should be used around the

vent to ensure a watertight seal.

13. Install two (2) wire spacer around the flex pipe. Slide the horizontal section of pipe over the flexible

liner. Ensure the wire spacers are positioned at either end of the pipe (refer to Figure 19 and 20).

14. Install the horizontal section of pipe through the wall thimble, ensure that this portion of pipe slides

onto the vent termination cap.

15. Slide the inside finished collar over the horizontal section of pipe and secure to wall using the screw

provided.