Initial installation – Enviro EG28-120 User Manual

Page 22

Advertising
background image

wall thimble will conceal it (see left image in

Figure 26).

7. Slide the decorative wall thimble up to the wall

surface and attach with the screws provided.

Apply decorative brass or chrome trim if desired

(see right image in Figure 26).

NOTES:
The four wood screws provided should be replaced

with the appropriate fasteners for stucco, brick,

concrete, or other types of siding.

For buildings with vinyl siding, a vinyl siding

standoff, should be installed between the vent cap

and the exterior wall (see Figure 27). Attach the

vinyl siding standoff to the horizontal termination.

The vinyl siding standoff prevents excessive heat

from possibly melting the vinyl siding material.

Note that the horizontal vent termination bolts

onto the flat portion of the vinyl siding standoff

(shaded area in Figure 27), so that an air space will

exist between the wall and the vent termination.

The horizontal run of vent pipe must be level and

should have a 1⁄4 inch rise for every one foot

of run towards the termination. Never allow

the vent to run downward. This could cause high

temperature and may present the possibility of a

fire.

The location of the horizontal vent termination

on the exterior wall must not be easily blocked

or obstructed. Refer to “Initial Installation - Vent

Termination Restrictions” section.

When installing a vent pipe in a chase the minimum

clearance to combustibles is 2” (5 cm).

Figure 27: Installing Vent Cap with Vinyl Siding

Stand-Off.

Figure 28: Installing Horizontal Vent Termination.

4. Position the horizontal vent termination in the center of the 10” (25.4 cm) x 10” (25.4 cm) hole, and

attach to the exterior wall with the four screws provided. Before attaching the vent termination to the

exterior wall, run a bead of non-hardening mastic around the edges, so as to make a seal between

the termination and the wall. The arrow on the vent termination should be pointing up, insure that

the proper clearances to combustible materials are maintained.

5. Before connecting the horizontal run of the vent pipe to the vent termination, slide the black

decorative wall thimble cover over the vent pipe.

6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the

cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a

minimum of 11⁄4” (3.2 cm) overlap. Secure the connection between the vent cap pipe and the vent

cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer wall

of the vent pipe. Use the two sheet metal screws provided to connect the straps to the vent pipe.

Bend any remaining portion of the sheet metal straps back towards the vent cap, so the decorative

Initial Installation

QUALIFIED INSTALLERS ONLY

22