Clearances to combustibles - freestanding, Alcove clearances - freestanding, Installation – Enviro Meridian User Manual

Page 13

Advertising
background image

Minimum

6" (150mm)

This pellet stove requires floor protection. The floor protection must be non-combustible, extending beneath

the stove the full width and depth of the unit including 6“ (150 mm) in front for ember protection.

A

LCOVE

C

LEARANCES

- F

REESTANDING

:

Figure 10: Meridian on Floor

Protection.

Minimum Width

36" (914mm)

Minimum Height

48" (1219mm)

Maximum Depth

30" (762mm)

Back wall

S

id

e

w

al

l

Adjacent

wall

2"

(51mm)

3" (76mm)

6"

(152mm)

Installation

C

LEARANCES

TO

C

OMBUSTIBLES

- F

REESTANDING

:

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for

serving, routine cleaning and maintenance.

Figure 11: Minimum Clearances to Combustibles for

Freestanding Meridian.

Figure 12: Alcove Clearances Freestanding Meridian.