Thermostat installed, Slider/damper setting, Installation – Enviro Meridian User Manual

Page 32

Advertising
background image

2. Open the right cab side to expose thermostat wires and disconnect. Install 18 gauge (see W

IRING

D

IAGRAM

) or heavier wire through the grommet in the back, from the stove to the thermostat. Connect

thermostat wires to red wires provided.

3. To set the thermostat jumper to the desired mode, remove the two (2) screws holding the circuit board

control panel in place. Lower the board and pull out to change jumper.

S

LIDER

/D

AMPER

S

ETTING

:

THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE

THE AIRFLOW THROUGH THE PELLET STOVE.

A Qualified Service Technician or Installer must set the Slider Damper.

The slider damper should be set only on a hot stove (operating for thirty (30) minutes or more) by placing

a Magnahelic Pressure Gauge in the firebox (test port is located in the center of the stove just below

the door opening). Set the slider damper so that the pressure reads 0.11” w.c. (.028 KPa) on HIGH

A) HI / LOW: When the

jumper is placed on

only one of the J9 pins,

then the control board

is in a HI / LOW mode

of thermostat operation

(factory setting).

Remove jumper wire and install thermostat

wires here

ON / OFF OPERATION: If

the control board is placed with

J9 jumped then the control

board is in a ON / OFF mode

of operation. In the ON /OFF

thermostat mode, when the

thermostat calls for heat, the

unit will go through an ignition

sequence and light the stove.

Once lit the unit will operate at

the selected setting displayed on

the control board Heat Output

Indicator. Once the thermostat

stops calling for heat, the unit

will stop feeding pellets and

begin its shut down sequence

until cold then turn off.
1. Install the Low Voltage

Thermostat

(maximum

24V) in a location that is

not to close too the unit but

will effectively monitor the

desired area to be heated.

Figure 47: Pin Placement on Circuit Board.

B) ON / OFF: If both

pins of J9 are jumped

(covered), the control

board is in an ON / OFF

mode of thermostat

operation.

Installation

T

HERMOSTAT

I

NSTALLED

:

This control board can be placed into two (2) different modes:
HI / LOW OPERATION: When the jumper J9 is not jumped then the control board is in a HI / LOW

mode operation. If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or

idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will

go to the setting that is displayed on the control board Heat Indicator. If the heating load is not great

enough when the stove is on low, the high limit switch will turn the stove off and the switch will have

to be manually reset. To reset the high limit switch, remove the right cabinet side. The switch is found

behind the control panel. Avoid setting off the high limit switch.