Installation – Enviro Meridian User Manual

Page 19

Advertising
background image

Exhaust Tube

3" (75mm) or 4" (100mm)

"PL" or "L" vent

Wall Thimble

45° Elbow with screen

or Termination Cap

Fresh Air Intake

High Temperature RTV

Silicone Required

Wall framing

Wall thimble

Termination

cap

Vent pipe

Horizontal frame

for thimble

ENVIRO Meridian

• This is due to the back pressure in the

exhaust caused by airflow around the

structure.

• All sections of pipe must have three (3)

screws evenly spaced and all horizontal

and vertical vent sections located within the

house must have a bead of high temperature

silicone installed on the male end of the pipe

before installation to create a gas tight seal.

• The termination must be 12 inches (30 cm)

from the outside wall and 12 inches (30 cm)

above the ground.

• A 45° elbow with a rodent screen may be

used in place of the termination cap (or

stainless steel termination hood).

Installation

Figure 23: Straight through wall Installation.

10. The

pipe must

extend at least

12” (30 cm) away

from the building.

If necessary, bring

another length of

pipe (PL type) to

the outside of the

home to connect to

the first section. Do

not forget to place

high temperature

silicone around the

pipe that passes

through

the

thimble.

11. Install a vertical

pipe, or if all

requirements

for

direct

venting

are met, install

vent termination. The stainless steel cap termination manufactured by the vent manufacturer is

recommended. However, when the vent terminates several feet above ground level and there are no

trees, plants, etc. within several feet, a 45° elbow can be used as termination. The elbow must be

turned down to prevent rain from entering.

NOTE:
• Some horizontal through wall installations may require a “T” and 3 to 5 feet (91 to 152 cm) of vertical

pipe outside the building to help naturally draft in the unit.

• This may be required if a proper burn cannot be maintained, after the stove has been tested and the

airflow set.

Figure 24: Straight through Wall Installation - Side View.