Installation – Enviro Meridian User Manual

Page 24

Advertising
background image

Installation

I

NSTALLATION

WITH

E

XTERIOR

M

OUNTED

E

XHAUST

B

LOWER

- F

REESTANDING

:

The MERIDIAN can be equipped with an externally mounted exhaust blower (PART #20-070). This

optional kit will include all components necessary to install the exhaust blower on any external vertical

wall surface.
Choose a location for your stove that meets the requirements stated in this manual and allows installation

with the least amount of interference to house framing, plumbing, wiring, etc.

Included in the exterior mounted exhaust blower kit are:

1 - Exhaust blower housing box.

1 - Blower cover plate.

1 - Hardware bag

Exhaust motor must be

replaced with cover

Left side with cab side

removed

Exhaust motor

Complete assembly - Exterior

blower & housing

1. Open the left side of the unit and the back grill and

disconnect the Exhaust Blower wires from the harness.

Remove the exhaust blower by undoing the six (6) 1⁄4 hex

head sheet metal screws that fasten the blower to the

housing.

2. Remove the back grill from the exterior exhaust vent

housing and remove the round cover plate installed on the

blower housing.

3. Install the round cover plate over the gasketed opening in

the stove where the exhaust motor was removed from.

4. Install the exhaust blower motor in the Exterior Vent

Housing Box onto the exhaust blower housing.

5. Follow the procedures for I

NSTALLATION

- H

ORIZONTAL

E

XHAUST

T

HROUGH

W

ALL

I

NSTALLATION

- F

REESTANDING

. Place the unit in

the desired location. Cut the hole in the wall at the desired

location. Install a wall thimble.

6. Drill holes in the wall thimble in the corresponding locations

for wire and fresh air if needed. Install wire clamps and

feed wire through the hole in the thimble into the house.

Tighten clamp on wire and attach green ground wire (at

the symbol) with the screw and star washer provided.

7. Attach a short or an adjustable section of 3” of double wall

pellet vent through the wall thimble to the stove. Seal all

joints with silicone. Maintain clearances to combustibles.

8. Apply silicone to the pipe in the Exhaust Box, slide the

pipe into the exhaust vent. Mount the Exhaust Box to the

house. Reinstall the back grill on the Exterior Vent Housing

Box. Apply normal venting practices when installing the

vertical vent pipe.

9. Connect the wires in the stove. Re-install the Left side and

Back Grill on the stove.

10. Set the Slider Damper as described in the I

NSTALLATION

-

S

LIDER

/D

AMPER

S

ETTING

“ section.

Figure 31: Exterior Exhaust Blower.

24

Advertising