Interface Specifications

Transmission procedures
Ready/Busy:

l

The DTR signal level changes to HIGH when the printer is ready

to receive data (or to LOW if set for inverted operation by

SelecType).

l

The DTR signal level changes to LOW when the printer is not

ready to receive data (or to HIGH if set for inverted operation by

SelecType).

XON/XOFF:

l

When the printer is ready to receive data, it sends an XON

(11 hex) to the host computer through the TD line for the

RS-232C interface or SD+ and SD- lines for the RS-422A

interface. When ROBUST-XON is set to ON (by SelecType), and

data is not received within one second of the XON signal being

sent, the printer sends an XON signal every second. If ROBUST-

XON is set to OFF, the printer sends only one XON signal.
When the printer is not ready to receive data, it sends an XOFF

(13 hex) to the host computer through the TD line for the

RS-232C interface or SD+ and SD- lines for the RS-422A

interface.
The printer is ready to receive data when it is on line, no error

conditions exist, and the buffer is not filled above the overload

value set with SelecType.

The printer is not ready to receive data when it is off line or

when it is on line but the remaining capacity of the data buffer is

less than the overload buffer value.