3) MAIN BURNERS WILL

NOT LIGHT

Make sure gas valve knob is

in the “ON” position.

SEE PAGE 8 FIGURE 6.

Correct if necessary.

Turn valve to the “ON”

position.

Make sure that the “ON-OFF

THERMO” switch is in the

“ON” position.

Turn switch “ON”.

Make sure that the

thermostat is “NOT” in the

lowest position.

Turn thermostat “UP”.

Replace damaged wires as

necessary. Gently squeeze

connectors with a pair of

pliers and reinstall wires.

Make sure that all control

wires are not damaged,

broken or frayed and that all

wire connections are tight.

Tighten the two screws on

valve if necessary

“TP/TP-TH” terminals on

valve.

Make sure that the

thermopile connections are

tight on the valve.

Make sure millivolt readings

from thermopile are within

manufactures

specifications. MAKE SURE
MILLIVOLT READINGS ARE

CONSTANT.

SEE PAGE 6 FIGURE 8.

Place leads of multimeter

on the “TP/TH-TP”

terminals on gas valve. If

the readings are less than

145mV DC, replace

thermopile

Continued on next page.

Sherwood Industries Ltd.

ENVIRO

PAGE 9

Advertising