Enviro C-10100 User Manual

Page 8

Advertising
background image

190 mv DC

CHECKING THERMOPILE FOR PROPER VOLTAGE

Place the leads of the multimeter on the TP/TH and TP

terminals on the valve as shown.

With the switch in the “ON” position, the readings should

be approximately 190mV DC (this an average reading) or

greater for proper Thermopile operation.

The main burners may not come ON if the readings are

less than 145mV DC.

If a thermostat has been installed. Place the

ON/OFF/THERMO switch in the THERMO position; place

the leads of the multimeter on the TP/TH and TH terminals

on the valve or on the connections at the thermostat.

MV reading should be higher than 190 mV DC for proper

valve operation.

THESE READINGS SHOULD BE CONSTANT WITH NO

FLUCTUATION.

When using a S.I.T EUROSIT 630 SERIES gas valve, place

one lead from the multimeter on the thermocouple lead and

the other lead into the adapter located on the back of the

valve, there are two blue wire a inserted into this adapter.

2 to 6mv DC

THERMOCOUPLE

CHECKING

THERMOCOUPLE FOR

PROPER VOLTAGE

Place one lead from the

multimeter on the

thermocouple lead, and the

other lead from the

multimeter on the back of

the valve where the blue

wire is soldered to the valve.

These readings should be

between 8 and 16mV DC.

If these readings are 2 to 6

mV DC, the Thermocouple

should be replaced