7) blower diagnosis all models – Enviro C-10100 User Manual

Page 21

Advertising
background image

Check to make sure that the fan is plugged in.

7) BLOWER DIAGNOSIS

ALL MODELS

Make sure the fan control knob is in the “ON”

position.

Make sure the two wires are connected to the

fan temperature sensor.

Make sure that the two wires are connected to

the blower.

Make sure there are no broken, damaged or

frayed wires.

Make sure that the fan sensor is secure and that

it is not damaged.

Using a supply cord connected

to the blower, plug the blower

directly into wall outlet.

By pass the fan temperature

sensor with a jumper wire.

By pass the fan controller with

jumper wire.

a

If the blower does not work,

replace the fan controller.

If the blower works, replace

the fan temperature sensor

If the blower does not work,

replace the blower.

MAKE SURE THAT THE FAN SENSOR IS AT OPERATING

TEMPERATURE BEFORE TESTING THE FAN CONTROLLER.