Adjust pilot if necessary.

Make sure pilot flame engulfs

the thermopile and does

“NOT” have a yellow

luminous flame.

SEE PAGE 4 FIGURE 4.

4) MAIN BURNERS WILL

NOT STAY LIT

Check outlet gas pressure.

Check for clogged pilot

injector or blocked air inlet.

Using a multimeter check

thermopile. If not constant

replace thermopile.

Make sure millivolt readings

from thermopile are constant.

Make sure all wiring is not

damaged or broken and all

connections are tight.

Correct if necessary.

By pas spill switch.

If unit starts, replace spill

switch.

B-VENTED MODELS

Check spill switch.

Check to make sure the vent is

drafting properly.

Check for spillage.

SEE PAGE 12.

Make sure all venting meets

manufactures specifications

as well as local gas and

building code requirements.

Correct if necessary.

Check chimney for blockage

or restriction.

Correct if necessary.