Enviro C-10100 User Manual

Page 9

Advertising
background image

2) PILOT WILL NOT STAY

LIT

Use a manometer on the inlet

side of the valve to measure

gas pressure. Adjust inlet

pressure or contact your gas

supplier.

Make sure the gas pressure is

correct for type of fuel you are

using.

SEE PAGE 5 FIGURE 7.

Thermocouple should be the

same height as the pilot hood.

Make sure pilot flame is

engulfing the top 3/8” of the

thermocouple.

SEE PAGE 2 FIGURE 2.

Adjust pilot as required.

Check for clogged pilot

injector.

Make sure thermocouple

connections on valve are

tight.

DO NOT OVER TIGHTEN!!!

Thermocouple connections

should be hand tight plu1/4

turn.

Clean thermocouple ends

with Emery cloth or an

abrasive sponge.

DO NOT USE A METAL FILE.

Replace if damaged.

Make sure the thermocouple

line has no kinks and is clean

on both ends. Also check the

thermocouple for damage.

Using a multimeter, insert

adapter between valve and

thermocouple, if the readings

are less than 2 TO 6 mV DC,

replace thermocouple.

SEE PAGE 6 FIGURE 8.

Make sure the thermocouple

has proper voltage (DC

VOLTAGE).