background image

28

Micro Motion

®

Model 2400S Transmitters

Dimensions and Specifications

A.4

Electrical connections

Model 2400S Analog

Input and output connections

Two pairs of wiring terminals for transmitter inputs/outputs. Screw terminals accept
solid or stranded conductors, 26 to 14 AWG (0,14 to 2,5 mm

2

).

Power connections

One pair of wiring terminals accepts AC or DC power. One internal ground lug for
power supply ground wiring.

Screw terminals accept solid or stranded conductors, 26 to 14 AWG
(0,14 to 2,5 mm

2

).

Digital comm maintenance
connections

Two clips for temporary connection to the service port.

Two clips for temporary connection to HART/Bell 202 terminals.

Model 2400S PROFIBUS-DP

PROFIBUS-DP segment

One pair of wiring terminals for connection to PROFIBUS-DP segment. Connection
type:

• Screw terminals accept solid or stranded conductors, 26 to 14 AWG

(0,14 to 2,5 mm

2

).

• Five-pin PROFIBUS-DP M12 (Eurofast) female connector (optional).

Power connections

One pair of wiring terminals accepts AC or DC power. One internal ground lug for
power supply ground wiring.

Screw terminals accept solid or stranded conductors, 26 to 14 AWG
(0,14 to 2,5 mm

2

).

Digital comm maintenance
connections

Two clips for temporary connection to the service port.

Model 2400S DeviceNet

DeviceNet segment

One pre-installed male 5-pin Eurofast connector for I/O and power supply wiring

Digital comm maintenance
connections

Two clips for temporary connection to the service port.