Installation, When installing this product, Mounting – Honeywell L7224A User Manual

Page 2: Warning

Advertising
background image

L7224A,C; L7248A,C,L OIL ELECTRONIC AQUASTAT

®

CONTROLLERS

68-0281EFS—06

2

Accessories:

W8735Y1000 Wireless Outdoor Reset Kit

W873ER1000 Wireless Outdoor Reset Module

C7089R1013 Wireless Outdoor Temperature Sensor

(requires W8735ER1000)

W8735S1000 AquaReset™ Outdoor Reset Kit (includes

50022037-002 Outdoor Reset Module and

C7089U1006 Outdoor Temperature Sensor)

W8735S1008 AquaReset™ Domestic Hot Water Kit

(includes 50022037-005 Domestic Hot Water Module

and 32003971-003 Sensor)

W8735S3000 EnviraCOM™ Alarm Module

C7089U1006 Outdoor Temperature Sensor (used with the

50022037-002)

32003971-003 Temperature Sensor (used with

50022037-005)

Sensor (See Table 2).

14,000,485-016 1/4 in. (6.35 mm) diameter, 1-1/4 in.

(31.75 mm) long glass cartridge Fuse, 1A, Slow-Blow.

120650 Heat Conductive Compound.

121371AA Sensor Well Clamp.

Table 1. Wells for L7224A,C; L7248A,C,L Controllers.

Table 2. Sensors for L7224A,C and

L7248A,C,L Controllers.

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow

them could damage the product or cause a

hazardous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for

your application.

3. The installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these instructions.

5. Set High Limit, Low Limit and Low Limit Differential

to the settings recommended by the boiler OEM.

6. Record the maximum High Limit setting from the

replaced controller in the text box provided on the

cover insert label.

7. Record the High Limit setting at time of installation

in the text box provided on the cover insert label.

WARNING

Electrical Shock Hazard.

Can cause severe injury, death or property

damage.

Disconnect power supply before beginning

installation to prevent electrical shock or

equipment damage.

Mounting

The L7224A,C and L7248A,C,L models are available in a

well-mount, horizontal position, vertical position, or flush

mounted remote from the well versions. Dimensions for

the variety of mounting options are shown in Fig. 1. Note

that each identity will have only a single mounting option.

Fig. 1. L7224A,C; L7248A,C,L mounting dimensions in inches (mm).

Part

Number

Spud Size

in. (mm)

Insertion

in. (mm)

Insulation

in. (mm)

123869A 1/2 (12.7) NPT

3 (76.2)

1-1/2 (38.1)

123870A 3/4 (19.05) NPT 3 (76.2)

1-1/2 (38.1)

Part Number

Length in.

(mm)

Application

50001464-001

12 (304.8) Well-mounted controls

50001464-003

24 (609.6) Flush-mounted controls

50001464-004

36 (914.4)

50001464-005

48 (1219.2)

M22147B

3/4

(75)

5-11/16

(145)

3/8

(10)

2-5/8 (67)

7-1/8

(181)

6-1/2

(166)

3-13/32 (86)

2x 1/4 (7) x 3/8 (9)

1/16 (2)

1-3/16

(30)

3-1/32

(77)

2-1/16 (53)

1-1/8 (29)

4-1/4 (109)

Advertising