Honeywell STR12D User Manual

Page 22

Advertising
background image

34-ST-03-64

Page 22

STR14A

STR12D & 13D

14G & 17G

TABLE II - SEALS (continued)

_ _ _ _ _ _ _ _ _ _ _ 0

_ _ _ _ _ _ _ _ _ _ _ H

6

6

6

_ _ _ _ _ _ _ _ _ _ _ J

6

6

6

(Metal plug material

_ _ _ _ _ _ _ _ _ _ _ M

6

6

6

will be the same as

_ _ _ _ _ _ _ _ _ _ _ N

6

6

6

Cal. ring material if

_ _ _ _ _ _ _ _ _ _ _ P

6

6

6

metal plug is chosen -

_ _ _ _ _ _ _ _ _ _ _ Q

6

6

6

SS Plug for CS Lower)

_ _ _ _ _ _ _ _ _ _ _ R

6

6

6

_ _ _ _ _ _ _ _ _ _ _ S

6

6

6

Table II continued below

*

Standard facing 125-250 AARH RF (raised face) serrated surface finish.

**

Limited vacuum availability.

***

Minimum static pressure requirement. No vacuum allowed. See Specifications Figure 15.

****

Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation

a

Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS non-wetted parts

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.

STR12D & 13D

STR14A

14G & 17G

TABLE II - SEALS (continued)

ANSI 150

22

_ _ _ BCA _ _ _ _ _ _

t

4

ANSI 300

22

_ _ _ BCC _ _ _ _ _ _

t

4

ANSI 150

22

_ _ _ BGA _ _ _ _ _ _

t

4

ANSI 300

22

_ _ _ BGC _ _ _ _ _ _

t

4

ANSI 150

22

_ _ _ BDA _ _ _ _ _ _

t

4

ANSI 300

22

_ _ _ BDC _ _ _ _ _ _

t

4

ANSI 150

22

_ _ _ BFA _ _ _ _ _ _

t

4

ANSI 300

22

_ _ _ BFC _ _ _ _ _ _

t

4

1/2"

ANSI 150

23

_ _ _ CAA _ _ _ _ _ _

ANSI 150

23

_ _ _ CCA _ _ _ _ _ _

ANSI 300

23

_ _ _ CCC _ _ _ _ _ _

ANSI 150

22

_ _ _ CGA _ _ _ _ _ _

ANSI 300

22

_ _ _ CGC _ _ _ _ _ _

ANSI 150

22

_ _ _ CDA _ _ _ _ _ _

ANSI 300

22

_ _ _ CDC _ _ _ _ _ _

1/2"

ANSI 150

22

_ _ _ DAA _ _ _ _ _ _

ANSI 150

23

_ _ _ DCA _ _ _ _ _ _

ANSI 300

23

_ _ _ DCC _ _ _ _ _ _

ANSI 150

23

_ _ _ DGA _ _ _ _ _ _

ANSI 300

23

_ _ _ DGC _ _ _ _ _ _

ANSI 150

23

_ _ _ DDA _ _ _ _ _ _

ANSI 300

22

_ _ _ DDC _ _ _ _ _ _

ANSI 150

22

_ _ _ DFA _ _ _ _ _ _

ANSI 300

22

_ _ _ DFC _ _ _ _ _ _

Table II continued next page

*

Standard facing 125-250 AARH RF (raised face) serrated finish.

**

Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.

Two 1/2" with plastic plugs

Selection

Flange

Pressure

Rating *

None

One 1/4" with plastic plug

One 1/4" with metal plug

Two 1/4" with plastic plugs

Two 1/4" with metal plugs

One 1/2" with plastic plug

One 1/2" with metal plug

2"

1-1/2"

3"

4.1"

2.9"

1-1/2"

1-1/2"

Flush Flanged

Seal

Flange

Size

Diaphragm

Diameter

Connections
and Plugs****

Flushing

2"

Selection

Construction - See Spec.

Figure 34-ST-03-64

Const. - See

Spec. Figure 34-

ST-03-64

Two 1/2" with metal plugs

1"

Flush Flanged

Seal with Lower

2.4"

3"

1"

2"

1"

Advertising