Installation – Harman Stove Company The Harman Accentra Pellet Insert User Manual

Page 12

Advertising
background image

13

Installation

7. If the room sensor is used as a return air sensor
rather than a room thermostat/sensor, the black cable
will not be used. The room sensor itself (gray cable
with black and red wires) will be connected to the blue
twisted wires from the control board.
Note: The stove body must be able to slide out of the
shell to the limit of the power cord wires for cleaning
and service. Therefore, if the room sensor is connected
as a return air sensor, the wire should be connected
long enough to allow this, but not too long that it would
get tangled or pinched anywhere.
Notice: The male/female connections between the
mounting shell and the stove body should always be
maintained. Wirenut or taped splices should never be
used.

Connecting the room sensor as a return air sensor

• Insert the sensor end of the wire from the rear of the

mounting frame through the hole as shown in fig. 24 .

• Tyrap the sensor end so that the sensing tip is in the

middle of the front return air opening. See Fig. 25.

• Tyrap the sensor wire to the inside of the mounting

frame up to the cord grounding location. Follow the
power wiring to where you make the male/female ter-
minal connection to the twisted blue wires.
There are (2) crimp-on connectors in the hardware pack
that must be installed on the internal ends of the room
sensor wires.

Side Return Air Holes

8. Install the (4) 3/8-16 x 1" leveling bolts into the
threaded holes in the bottom pan of the mounting shell.
The front two leveing bolts may not be necessary, but
the back two will need to be used to level the wing so
that it is flush with the fireplace face. See Fig. 26.

R3

Fig. 24

Fig. 25

3/8 x 16 tapped

leveling bolt holes

Fig. 26

1/2" threaded
wedging rods

(5) bolt down holes