ESP Control

Status light error messages:

1 Blink: Indicates control board self diagnostic fail-
ure. This requires a manual reset*.
3 Blinks: Indicates ESP (Exhaust Sensing Probe)
failure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not in-
stalled. If a Room Sensing Probe is then installed,
the status light will automatically reset.
NOTE: Unit will not start in "AUTO" with this status
error.
5 Blinks (In Igniter Auto. Mode Only): Indicates
that the unit has failed to light within the 36 minute
start cycle. To reset - Turn Mode Selector to "OFF",
then turn to either mode again.)

6 Blinks : Indicates that the control has calculated
poor or incomplete combustion occurring for more
than 50 minutes.
A six blink status may be set if the stove is allowed
to run out of pellets. To reset, turn mode selector to
"OFF" then back on to the desired mode. If the unit
was not out of pellets, see Troubleshooting section,
Page 24, for more details.
* Manual reset- disconnect power cord for a few
seconds and reconnect. If error still occurs call your
Dealer.

Feed adjuster
Sets the maximum
feed rate

Test
Runs all motors at full
speed for one minute
to check operation.
After two minutes the
s to ve wil l go to
minimum burn and
the b lo we rs wil l
alternate from high to
low every minute to
remind you that you
a re s ti ll i n "Tes t
Mode".

Igniter switch
Set to appropriate
Start-Up mode.

Di stri bu ti on B lo we r
speed adjustment range.
L = low
H = high
Variable speed anywhere
b etwe en L a nd H;
although as the stove
temp. goes up , so does
the L and H scale.

Temp dial
Allows you to adjust the room temperature in Room Temp
Mode using the outer scale marked in degrees Fahrenheit.
It also allows you to adjust the stove temperature while in
Stove Temp Mode using the inner scale marked from 1 to 7.

Mode Selector
Allows you to choose between
Room Temp Mode, Stove
Temp Mode, or OFF. Also
a ll ows yo u to v ar y th e
distribution blower speed by
turning the knob to the high
or low side of each mode.

Power Light
Indicates power to the
control.

Indicates power to the
feed motor.

Indicates igniter is on.

Indicates power to
combustion blower

Status Light
Will be lit in either stove
or room temp mode when
pointer is not within off
position band except
after normal shut down.
Blinks to indicate errors
listed below.

Indicates power to
distribution blower.

Dealer Diagnostic Port
For dealer maintenance
only. Requires special DDM
monitor supplied to Harman
Dealers exclusively.

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Advertising