AFTER THE INSTALLATION IS COMPLETED

Harman Accentra Insert Zero Clearance Cabinet

See your dealer for part details

and installation instructions.

Harman Mantel System

Combustible materials are allowed to touch the cabinet anywhere behind the front mounting flanges except vent
clearance areas. The hearth substructure may be built of combustible material although a non-combustible hearth
surface (tile, stone, metal, glass) must extend as far as shown on the UL label.

Fig. 55

Fig. 56

Accentra Insert Zero Clearance Cabinet

B e su re t o us e ap-

proved pellet vent pipe wall
and ceiling pass- through
fittings to go through com-
bustible walls and ceilings.
Be sure to use a starting col-
lar to attach the venting sys-
tem to the flue stub and seal
the c onne ctio n with high
temperature silicone.

Harman Zero

Clearance cabinet

(top flue only)

Part #1-00-674070

Insert Wing &

Mounting Frame

Insert Body

When using 3" or 4" PL vent
pipe, the re mus t be a 3 "
clearance to combustibles.

A minimum of a 1" hearth is
required when using the

Harman Zero Clearance box.

Harman Zero Clearance Box
Flue Pipe Support (optional)
Part # 1-00-674119