Honeywell 191108AJ User Manual

Page 16

Advertising
background image

16

69-0643—1

Troubleshooting (Continued)

Problem

Check

Action

Room

— Thermostat circuits.

Heating mode—Move temperature

temperatures

setting levers 5

°

F [3

°

C] above room

are not correct

temperature. Heating system should

(continued).

start.
Cooling mode—Move temperature
setting levers 5

°

F [3

°

C] below room

temperature. Cooling system should
start. If the system does not operate,
call a qualified service technician.

Burner-on time

— Anticipator setting. (See Fig. 6

Increase anticipator setting by 0.05

too short.

for anticipator location.)

(e.g., 0.4 to 0.45). Observe burner
operation.

Burner-on time too

— Anticipator setting. (See Fig. 6

Decrease anticipator setting by 0.05

long.

for anticipator location.)

(e.g., 0.45 to 0.4). Observe burner
operation.

(continued)