69-0643—1
Problem
Check
Action
Thermostat setting
— Level position of thermostat.
Reinstall thermostat wallplate or
and thermometer
subbase. Use a spirit level.
reading disagree.
— Area around thermostat for
Thermostat should be about 5 ft
drafts or radiant heat.
[1.5m] above floor on an inside wall.
Contact qualified service technician for
change of location.
— Calibration of thermometer.
See Thermometer Adjustment section.
Timer does not run.
—Thermostat connections at the
two C terminals. If no
connections, timer needs
batteries in to run.
— Batteries may not have been
Install as shown in Fig. 2.
installed.
— Batteries may need
Replace with two new AAA alkaline
replacement.
batteries as shown in Fig. 2.
— If new batteries are installed
Replace thermostat.
and timer still does not run.