Warning, Two elbows, Top vent - horizontal termination - (continued) – Heatiator GDST3831I User Manual

Page 27

Advertising
background image

27

Heatilator • GDST3831I • 2127-900 Rev. L • 3/13

Figure 7.5

Two Elbows

V

1

Minimum**

H

1

+ H

2

Maximum

90 Elbow**

1/2 ft.

152 mm

1/2 ft.**

152 mm

1 ft.

305 mm

1-1/2 ft.**

457 mm

2 ft.

610 mm

2-1/2 ft.**

762 mm

4 ft.

1.2 m

3-1/2 ft.

1.1 m

6 ft.

1.8 m

4-1/2 ft.

1.4 m

14 ft.

4.3 m

H

1

+ H

2

Max. =14 ft. (4.3 m)

V

1

+ H

1

+ H

2

Max. = 40 ft. (12.2 m)

See Warning**

1. Top Vent - Horizontal Termination - (continued)

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).

WARNING**

Fire Risk.

• When using SLP-HRC-SS and SLP-HRC-ZC-SS

termination caps on top vented fi replaces, a one
foot minimum vertical vent section is required before

installing fi rst elbow

.

• When using DVP-TB1 termination cap on top vented

fi replaces, a three foot minimum vertical vent section
is required before installing fi rst elbow.

• When using any other cap, a section of vertical pipe (12 inches

minimum) MUST be installed prior to attaching a 90° elbow.