Venting, Caution – Harman Stove Company Advance Pellet Stove User Manual

Page 13

Advertising
background image

13

#2 Preferred method

This method also provides excellent venting for

normal operation but requires the stove to be installed
farther from the wall. The vertical portion of the vent
should be three to five feet high and at least three inches
from a combustible wall. This vertical section will pro-
vide natural draft in the event of a power failure.

#1 Preferred method

This method provides excellent venting for nor-

mal operation and allows the stove to be installed clos-
est to the wall. One inch from the wall is safe; how-
ever, two or three inches allows better access to re-
move the rear panel. The vertical portion of the vent
should be three to five feet high. This vertical section
will provide natural draft in the event of a power failure.

Fig.20

Fig.21

Venting

KEEP COMBUSTIBLES (SUCH AS

GRASS, LEAVES, ETC.) AT LEAST 3

FEET AWAY FROM THE FLUE OUTLET

ON THE OUTSIDE OF THE BUILDING.

CAUTION

3 ft.

to

combustibles

3 ft.

to

combustibles