Installation – Harman Stove Company Advance Pellet Stove User Manual

Page 8

Advertising
background image

8

When installing and operating your Harman Advance

Pellet Stove, respect basic safety standards. Read these
instructions carefully before you attempt to install or oper-
ate the Advance. Failure to do so may result in damage to
property or personal injury and may void the product war-
ranty.

Consult with your local building code agency and in-

surance representative before you begin your installation
to ensure compliance with local codes, including the need
for permits and follow-up inspections.

Several issues must be addressed when selecting

a suitable location for your Advance Pellet Stove. Observ-
ing required clearances to combustible materials, the prox-
imity to a safe chimney or venting system, and the acces-
sibility of electrical supply must all be considered. In addi-
tion, selecting a location that takes advantage of the
building's natural air flow is also desirable to maximize
the heating effectiveness of the heater. In many cases,
this is a central location within the building.

Adequate combustion and ventilation air must be pro-

vided.

Place the stove on a noncombustible floor or UL ap-

proved floor protector that extends 6 inches to the front, 6
inches to the sides and 1 inch to the rear of the stove. Fig.
8.

Place the stove away from combustible walls at least

as far as shown in figures 6, and 7.

Note that the clearances shown are minimum for

safety but do not leave much room for access when clean-
ing or servicing. Please take this into account when plac-
ing the stove.

Mobile Home Installation

AFTER THE INSTALLATION IS COMPLETED

Before the first fire is lit, check and record

the high and low draft reading numbers on page
10. Make adjustments to the low draft at this time,
if necessary. See page 10.

Installation

6"

6"

6"

Fig.8

1"

When installing this stove in a mobile home several

requirements must be followed:

1. The unit must be bolted to the floor. This can be

done with 1/4" lag screws throught the 2 holes in
the base plate shown in Fig. 13, Page 9.

2. The unit must also be connected for the outside

air. See page 12.

3. Floor protection and clearances must be followed

as shown above.

4. Unit must be grounded to the metal frame of the

mobile home.

CAUTION: This appliance must be vented to the

outside.

Due to high temperatures, the stove should be placed

out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards

of high surface temperatures and should stay away to
avoid burn to skin and/or clothing.

Young children should be carefully supervised when

they are in the same room as the stove.

Clothing and other flammable materials should not

be placed on or near the stove.

FL

O

O

R

PR

O

TE

C

TO

R

7"

7"

Fig.6

1"

10"

Fig.7

FLOOR PROTECTOR

Installation and repair of this stove should be done by

a qualified service person. The appliance should be in-
spected before use and at least annually by a qualified
service person. More frequent cleaning will be required. It
is imperative that control compartments, burners, and cir-
culating air passageways of the stove be kept clean.

FLOOR