Servicing the battery pack, Storing batteries, Servicing the battery pack -3 storing batteries -3 – Hand Held Products 7450 User Manual

Page 109

Advertising
background image

13 - 3

LEDs

Servicing The Battery Pack

To service battery packs, insert batteries into the charging pockets and press the Condition button. The Condition LED will flash
during the conditioning cycle. This starts an automatic process in which batteries are completely discharged and then recharged
to full capacity in eight hours. The Condition and Calibrate cycle resets and calibrates battery data so that the user gets longer,
more consistent performance from the batteries. HHP recommends that battery packs should be serviced, or calibrated, once a
month.

Because the Dolphin QuadCharger is accumulating battery pack information during the entire Condition and Calibrate cycle, it is
important not to remove the battery until the cycle has been completed and the Condition LED is no longer flashing. Batteries
inserted after the “Condition and Calibrate” switch has been depressed will receive a standard charge. The chart below describes
the Status LEDs during the Condition and Calibrate cycle:

Status of LEDs during Condition and Calibrate Cycle

Storing Batteries

To maintain top performance from batteries, follow the guidelines below when storing them:

Avoid storing batteries outside of the specified temperature range of -4 to 104° F ( -20 to 40°C) or in extremely high humidity.

For prolonged storage, do not keep batteries stored in a charger that is connected to a power source.

During long-term storage, battery deactivation may tend to occur which may cause charging to stop early during recharging after
storage. This issue can be handled by charging and discharging the battery several times. Also, the first charging after prolonged
storage may yield a lower than normal capacity. While this will vary depending on the storage conditions, charging and
discharging the battery several times will almost completely restore capacity.

Status LED

Description

Green

Charging is complete and battery is ready for service.

Orange

Battery is being charged at a maximum charge rate

Red

Error was encountered during charge cycle

Status LED

Description

Solid Green

Cycle is complete. Battery remains in trickle charge until
removed from the charger.

Flashing Orange

Battery is being conditioned

Solid Red

Error was encountered during charge cycle

Advertising