hussmann GSVM User Manual

Page 9

Advertising
background image

9









Flat

1

1/2

Upslope 17ºTilt

30ºTilt

Bottom Sheet Metal Area

250#

N/A

N/A

Stand. 13”/15” shelves

250#

250#

75#

Stand. 13”/15” shelves w/optional
upslope 6º adapters

125#

N/A

N/A

Optional Wire Baskets

200#

100#

30#

OPERATION and MAINTENANCE -

It is important that the two

previous sections of this installation
booklet have been read and followed
carefully before attempting to start up
the equipment.

A thorough inspection should be

made prior to start up to assure that
there are no loose nuts, bolts, electrical
connections or refrigeration lines
rubbing or chafing. Turn the power
switch to the ON position. ALLOW
system to reach normal operating
temp.prior to
loading any
product.
This cabinet
has a
forced-air
curtain that
flows over the
top of the
product.





See SHELVES for the special

loading instructions. Air flows out of the
honeycomb diffuser located above the
product, across the product, and into the
return duct. The honeycomb can be
removed for cleaning.

TEMPERATURE CONTROL –

Interior cabinet temperatures are

controlled through the use of a bulb and
capillary type temperature control. The
control is located in the electrical box.

The sensing bulb is mounted on the

top of the evaporator coil on the 4060 and
4072. On the 5272 it is located on the rear
wall behind the evaporator coil. Be sure
to disconnect power supply prior to any
service work on the control.

The control is factory pre-set

between 19º and 21ºF for the GSVM4060,
4072 and - 26º to 28ºF on the GSVM5272 to
maintain between 35º and 40ºF interior
cabinet average temperatures.

The differential is set at 8-10ºF or

alittle over halfway towards “MAX”.
Donot adjust lower or evap. icing will
occur. It can be adjusted to other desired
temperatures by turning the dial to the
corresponding dial face temperatures. The
indicated dial temperature will not directly

Advertising