T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS

69-1510-4

10

THERMOSTAT INFORMATION

1. Press the Time

∆ key to access the thermostat

information.

2. Press the increase key to display the production

date code. The first two large digits are the month
and the third digit is the last digit of the year.
(Example: 027 = February 1997).

3. Press the increase key again to display the

software identification code.
(Example: 02 = software ID code 2).

4. Press the increase key again to display the soft-

ware revision number.
(Example: 001 = Revision number 1).

5. Press the increase key again to display the

EEPROM identification code.
(Example: 314 = EEPROM ID 314).

6. Press the Run Program key to exit the system test.

The system test times out after four minutes
without any key presses.

CHECKOUT

Outdoor Temperature Sensor

(Select Models)

Allow the outdoor temperature sensor to absorb the
outdoor air for a minimum of five minutes before taking a
reading.

M14613

M14614

M14615

M14616

M14617