T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS

7

69-1510-4

IMPORTANT

Review the settings to confirm that they match
the system. Press Run Program to exit the
Installer Setup. The thermostat has saved the
Installer Setup changes and initiated a reset in
order to operate using the new settings. Be sure
to set the current day and time immediately.

Temperature
display
adjustment.

37

0

No difference in
displayed
temperature and
actual room
temperature.

1.5 thru
-1.5

.5—Display adjusts to

0.5°C higher than
actual room
temperature.

1.0—Display adjusts to

1.0°C higher than
actual room
temperature.

1.5—Display adjusts to

1.5°C higher than
actual room
temperature.

-.5—Display adjusts to -

.5°C lower than actual
room temperature.

-1.0—Display adjusts to -

1.0°C lower than actual
room temperature.

-1.5—Display adjusts to -

1.5°C lower than actual
room temperature.

Furnace Air
Filter Timer.

43

0

Off

1, 2, 3,
4

1 – 10 days
2 – 30 days
3 – 60 days
4 – 120 days
(Time counted when heat,
cool or fan is running.)

Humidifier
Pad Monitor.

44

0

Off

1, 2, 3

1 – 90 days
2 – 180 days
3 – 365 days
(Time counted by calendar
days in heat mode.)

Ultraviolet
(UV) Air
Treatment
System Lamp
Monitor.

45

0

Off

1

1 – 365 days
(Times counted by
calendar days in any
mode.)

Table 3. Thermostat Installer Setup Options. (Continued)

Select

Installer Setup

Number (Press

Time

key to

change)

Factory Setting

Other Choices

(Press or key to change)

Actual

Setting

Display

Description

Display

Description