Mounting thermostat, T8602d chronotherm® iv programmable thermostats – Honeywell Chronotherm IV T8602D User Manual

Page 3

Advertising
background image

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS

3

69-1510-4

Fig. 4. Typical hookup in heat and cool system with

one transformer.

Fig. 5. Typical hookup in millivoltage heating circuit.

Fig. 6. Typical hookup in millvoltage heating and

24 Vac cooling circuit.

Fig. 7. Correct wiring technique.

Mounting Thermostat

1. Engage tabs at the top of the thermostat and wall-

plate. See Fig. 7.

2. Press lower edge of case to close and latch.

NOTE: To remove the thermostat from the wall, first pull

out at the bottom of the thermostat; remove top
last.

Fig. 8. Mounting thermostat on wallplate.

L1
(HOT)

L2

M10347A

FAN
RELAY

Y

G

THERMOSTAT

HEAT
RELAY

R

W

COMPRESSOR
CONTACTOR

TRANSFORMER

B

HEAT
DAMPER

COOL
DAMPER

O

1

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT
PUMP SYSTEMS.

AVAILABLE ON SELECT MODELS. OT WIRES MUST HAVE A
SEPARATE CABLE FROM THE THERMOSTAT CABLE.

2

2

2

1

3

OT

OT

OUTDOOR
TEMPERATURE
SENSOR

3

RC

W

MILLIVOLT HEATING-ONLY
WALLPLATE

R

M2931

TH

TH/

PP

PP

MILLIVOLTAGE
GAS CONTROL

LIMIT
CONTROL

MILLIVOLTAGE
GENERATOR

PILOTSTAT
CONTROL
(IF USED)

M2942

TH

TH/

PP

PP

MILLIVOLTAGE
GAS CONTROL

LIMIT
CONTROL

MILLIVOLTAGE
GENERATOR

PILOTSTAT
CONTROL
(IF USED)

COOLING
CONTACTOR

W

G

R

RC

Y

O

L1
(HOT)

L2

1

FAN
RELAY

CHANGEOVER
RELAY

POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.

1

MILLIVOLT HEATING-24Vac
COOLING WALLPLATE

M4826

FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).

FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).

M14628

PRESS LOWER
EDGE OF CASE
TO LATCH.

ENGAGE TABS
AT TOP OF
THERMOSTAT
AND WALLPLATE.

A.

B.

Advertising